Search results for "Ventricular volume"
showing 6 items of 6 documents
Quantitative Assessment of Right Ventricular Volumes in Severe Chronic Thromboembolic Pulmonary Hypertension using Transthoracic Three-dimensional Ec…
2002
Evaluation of a three-dimensional reconstruction method to show the changes of right ventricular volume and systolic function when patients undergo pulmonary thromboendarterectomy for chronic thromboembolic pulmonary hypertension.In the examination of 11 patients (four female, seven male; age 56+/-10 years) before and after pulmonary thromboendarterectomy, end-diastolic and end-systolic right ventricular volumes were determined as a sum total of the calculated volumes of derived parallel slices of the right ventricle. Using a Tomtec workstation and a Vingmed CFM 800 echocardiography device, the acquired data were ECG-and respiration-triggered in the course of transthoracic examination, usin…
Left ventricular volume determination using Albunex.
1996
The aim of this study was to assess the ability of intravenous injection of Albunex to improve left ventricular volume determination in patients with various cardiac diseases. It is conceivable that the intravenous injection of microbubbles could improve echocardiographic left ventricular border delineation leading to improved interobserver variability. Echocardiograms were obtained during simultaneous intravenous injection of 0.08 and 0.12 ml/kg Albunex (four-chamber view). Within 6 hours after the recording of the contrast echocardiograms routine left heart angiography was performed. Volumes were measured using the slice method in native and contrast echocardiograms as well as in the angi…
Left ventricular volume determination using colour superpositioning of contrast echocardiograms
1995
Abstract Objective: To delineate the endocardium, selective colouring of contrast regions in left ventricular contrast echocardiograms was performed using digital image processing. Methods: Volume determinations were performed in end-diastolic and end-systolic frames before and after the injection of contrast agent into the left ventricle and were compared to cineventriculograms in 30 patients by two independent investigators. Results: The mean end-diastolic volume measured was 114 ± 44 ml in the native, 235 ± 79 ml in the contrast, 175 ± 70 ml in the color-superimposed (observer 1), and 187 ± 79 ml in the cineventriculographic images. Thus, native echocardiograms underestimated angiographi…
Tomographic left ventricular volume determination in the presence of aneurysm by three-dimensional echocardiographic imaging. I: Asymmetric model hea…
1996
To improve the accuracy of measurements of left ventricular volume in the presence of an aneurysm, we used three-dimensional echocardiographic imaging to analyze the shape of left ventricles in 23 asymmetric model hearts with eccentric aneurysms of different sizes, shapes, and localizations. A standard 3.75 MHz ultrasound probe with a rotation motor device was used to obtain a three-dimensional data set. By rotating the probe stepwise 1 degree, 180 radial ultrasound pictures were digitized. On the basis of the three-dimensional data set, the following parameters were determined and compared with the dimensions of the model hearts obtained by direct measurement: total left ventricular volume…
Microvascular obstruction in the right ventricle in reperfused anterior myocardial infarction: macroscopic and pathologic evidence in a swine model
2013
Right ventricular volume determination in isolated human hearts
1986
For right ventricular volume determination a new method was developed that took into account right ventricular imaging by apical two-dimensional echocardiography in the four- and two-chamber views. Right ventricular volume was calculated by subtraction of the partial volume of the left ventricle and interventricular septum from the total heart volume of the right and left ventricles including the interventricular septum. Accuracy of the subtraction method was evaluated in isolated human hearts by two-dimensional echocardiography and radiography. Regression analysis indicated that for both the echocardiographic and radiologic procedures, the subtraction method gave the best correlation with …